foto1
QUALITY IS OUR PRIORITY
foto1
TOGETHER WE GREAT
foto1
SAFETY IS MY LIFE
foto1
ACCURACY IS OUR CONCERN
foto1
WORK SAFE BE SAVE

Our Services

  • BANNER-1.jpg
  • BANNER-2.jpg
  • BANNER-3.jpg
  • BANNER-4.jpg

STANDARD AND QUICK RESPONSE SPRINKLERS

Standard Response Sprinklers are intended for use in fire sprinkler systems designed in accordance with the installation rules recognized by the applicable Listing or Approval agency. There are two types or response elements: bulb and solder. Series TY-B bulb type sprinklers are available in a variety of attractive finishes that blend well with their surroundings. When in service, a small bubble in the fluid contained in the bulb compensates for normal temperature changes. When heated, the fluid in the bulb expands and shatters the bulb, allowing water to be discharged. Series TY-L solder type sprinklers employ a link whose two sections are joined by solder with a predetermined temperature rating. Heat absorbed by the link is conducted directly to the soldered joint. When the solder melts, the link springs apart, releasing water that strikes the sprinkler deflector.

 

Quick Response Sprinklers are designed with a 3mm bulb or small nickel link to react more quickly at the specified temperature. They are available in pendent, upright, recessed, concealed, vertical sidewall, and horizontal sidewall styles. The narrow profile bulbs and attractive finishes of the Series TY-FRB provide specifiers with a wide variety of sprinklers for use in quick response applications. The versatile Quick Response TY-FRL Series provides the specifier with a solder type sprinkler for most commercial and industrial applications

Aplication

  • Office Buildings
  • Banks
  • Factories
  • Libraries
  • Theaters
  • Light & Ordinary Hazard Occupancies
  • Schools

 

EXTENDED COVERAGE SPRINKLERS

Extended Coverage Sprinklers are intended for the protection of areas larger than those specified in standard installation rules and for specific light, ordinary, or extra hazard occupancies. Extended coverage sprinklers are available in both standard response (EC) and quick response (QR-EC). They are available in upright, pendent, horizontal sidewall and recessed horizontal sidewall. These sprinklers are typically used in hotels, restaurants, office buildings, warehouses, and other areas where it is desirable to reduce the overall number of required sprinklers.

Aplication

  • Office Buildings
  • Hotels
  • Hospitals
  • Libraries
  • High-Piled Storage
  • “Big-Box” Retailing

 

STORAGE SPRINKLERS

Storage Sprinklers are intended for use in specific applications, including the protection of high-piled and rack storage of a variety of finished goods. These sprinklers can provide more water at lower pressures or more water over a greater area of coverage. In many instances, use of the storage sprinklers can eliminate the need for additional in-rack sprinklers. Intermediate level (in-rack) sprinklers are designed for use in rack storage sprinkler systems, where their thermally sensitive elements must be shielded from the water spray of higher elevation sprinklers that could operate during a fire. Intermediate Level Sprinklers are also used in applications such as beneath open gridded catwalks. These sprinklers are intended for use in fire sprinkler systems designed in accordance with the standard installation rules recognized by the applicable Listing or Approval agency (e.g., FM approval and UL Listing is based on NFPA requirements).

Aplication

  • High-Piled Storage
  • In-Rack Storage
  • Warehouse
  • High Challenge Occupacies

 

 

DRY SPRINKLERS

Dry Sprinklers have been specifically designed for areas in which the sprinkler may be subjected to freezing conditions. These sprinklers have been developed for use in all standard applications, as well as multiple unique scenarios. Tyco Dry Sprinklers are available in both quick and standard response, and come in a variety of finishes. These features, and the advanced engineering in the development of these sprinklers, offer the industry the most complete line of dry sprinklers available. Most models are listed in lengths up to 4'-0". The extended escutcheon option has up to 3" of adjustment.

Aplication

  • Unheated Warehouse
  • Freezing Conditions
  • Loading Docks
  • Covered Exterior Platform

 

SPECIAL PURPOSE SPRINKLERS

Special Purpose Sprinklers are intended for use in specific applications, including the protection of combustible concealed spaces and areas subject to corrosion. Also, these installations may need consideration for more water at lower pressures, or more water over a greater area.

Aplication

  • Attic Spaces
  • Retail Windows
  • High Security Institutions
  • Minimal Water Damage Conditions
  • High Temperature Conditions
  • Corrisive Conditions

 

SPRINKLER ACCESSORIES

Sprinkler Accessories are for use with the sprinklers and nozzles described in this catalog. Escutcheons are referenced by a style number and are available in brass, chrome or white finish. Please refer to the technical data sheet for additional information and a listing of what finishes are available

Aplication

  • Improve Appearances
  • Conceal Clearance Holes
  • Onsite Emergency Storage Supply
  • Protection from Mechanical or Physical Damage

NOZZLES & NOZZLE ACCESSORIES

Nozzles & Nozzle Accessories are designed for use in a variety of special hazard applications. Their uses include, but are not limited to, exposure protection, fire control, fire extinguishment, and explosion prevention. Many types of nozzles may be required to provide a properly designed special hazard fire protection system.

Aplication

  • Flammable Liquid Tanks & Operations
  • Equipment or Processes that Require Special Designs
  • Cable Trays
  • Clean Rooms
  • Conveyors
  • Cut-off Rooms
  • Engine Test Cells
  • Flammable Liquid Storage
  • Food Processing
  • Full Storage
  • Gas Turbines
  • Historic Sites & Museums
  • Industrial Process Equipment
  • Machining Centers
  • Ferries
  • Offshore Platforms
  • Telecom
  • Transformers
  • Vapor Supression

 

HOSE REEL

General features  for fixed dan swing type :

  • Side plates red epoxy powder finishing
  • Automatic hose reel has integrated automatic stop vatve which will open after 2 revolution of the reel
  • Threaded Inlet oonnectlon
  • Outlet connection for hose can be rolllted for laR and right direction
  • Waterwaysmade from non ferrous metals which ensure corrosion free•
  • Maximum working pressure 12bar, test pressure 18bar (EN671-1)
  • Side plates available in stainless steel

General Dimension  for fixed & swing type :

  • Drum Size : 19" or 22"
  • Hose Oiamter & length: 314• or 1· X 30 meter
  • Distance betwee drums :
  • 24 cm for fixed type - 29 cm for swing type

 

HYDRANT BOX

Hydrant box type C  memiliki ukuran (95 x 66 x 20) cm dan dapat menambung beberapa fire hydrant equipment. untuk lebih detail mengenai spesifikasi hydrant box type C sebagai berikut:

  • Size : (95 x 66 x 20) cm for outdoor
  • 1 roll Fire Hose PU Type, Size 2, 5 ” x 30 mtr, coupling Machino
  • 1 pc Hose Nozzle, Size 2, 5 ” coupling Machino
  • Material : 1,2mm Baja Mild
  • Proses Produksi : Dust Remover, Phospating & Zincchoramate Primer
  • Finalisasi : Top coat powder coating red signal

 

Clients

  • client1.jpg
  • client2.jpg
  • client4.jpg
  • client5.jpg
  • client6.jpg
  • client7.jpg
  • client8.jpg
  • client9.jpg
  • client11.jpg
  • client12.jpg
  • client13.jpg
  • client14.jpg
  • client15.jpg
  • pjb.jpg
  • tk.jpg
  • Untitled-03.jpg
  • Untitled-04.jpg
  • Untitled-06.jpg
  • Untitled-09.jpg